P-CAD Design Rule Check Report ====================================================================== C:\prj\1. SIMM-30\simm30-1x-1M.drc: Design Clearances (in mm): ------------------------------- Board Edge Clearance: Not Defined Silk Screen Clearance: Not Defined Hole-Hole Clearance: Not Defined Layer Clearances (in mm): ------------------------------- Layer Name Pad-Pad Pad-Line Line-Line Pad-Via Via-Line Via-Via Top 0.150 0.150 0.150 0.150 0.150 0.150 Bottom 0.150 0.150 0.150 0.150 0.150 0.150 Net Class Clearances (in mm): ------------------------------- Net Class Name Pad-Pad Pad-Line Line-Line Pad-Via Via-Line Via-Via Net Clearances (In mm): ------------------------- Net Name Pad-Pad Pad-Line Line-Line Pad-Via Via-Line Via-Via Net Class To Net Class Clearances (in mm): -------------------------------------------- Net Class Names Pad-Pad Pad-Line Line-Line Pad-Via Via-Line Via-Via Area Checked: ------------- DRC Extents: Entire Workspace DRC Report Options: ------------------- Net List Compare: Off Clearance Violations: On Text Violations: On Same-Parent-Component Pad Violations: On Net List Violations: On Unrouted Nets: On Unconnected Pins: Off Net Length Violations: On Silk Violations: On Copper Pour Violations: On Plane Violations: On Component Violations: On Drill Violations: On ---------------------------------------------------------------------- 24-Jan-25 05:33 Page 1 P-CAD Design Rule Check Report ====================================================================== Test Point Violations: Off DRC Errors: ----------- NETLIST VIOLATIONS: 0 warning(s) detected. 0 error(s) detected. CLEARANCE VIOLATIONS: 0 warning(s) detected. 0 error(s) detected. UNROUTED NETS: 0 warning(s) detected. 0 error(s) detected. Warning: Net length violation tests were not performed because of missing MinNetLength, MaxNetLength, or MatchedLength rules. NETLIST LENGTH VIOLATIONS: 0 warning(s) detected. 0 error(s) detected. SILK SCREEN CLEARANCE VIOLATIONS: Warning: Silk Screen clearance violation tests were not performed because of missing SilkscreenClearance rule. 0 warning(s) detected. 0 error(s) detected. TEXT VIOLATIONS: 0 warning(s) detected. 0 error(s) detected. WIDTH VIOLATIONS: Warning: Width violation tests were not performed because of missing Width rule. 0 warning(s) detected. 0 error(s) detected. COPPER POUR VIOLATIONS: ---------------------------------------------------------------------- 24-Jan-25 05:33 Page 2 P-CAD Design Rule Check Report ====================================================================== 0 warning(s) detected. 0 error(s) detected. PLANE VIOLATIONS: 0 warning(s) detected. 0 error(s) detected. COMPONENT VIOLATIONS: 0 warning(s) detected. 0 error(s) detected. DRILL VIOLATIONS: Warning: Hole to hole clearance violation tests were not performed because of missing HoleToHoleClearance rule. 0 warning(s) detected. 0 error(s) detected. DRC Summary: ------------ Netlist: Errors: 0 Warnings: 0 Ignored Errors: 0 Clearance: Errors: 0 Warnings: 0 Ignored Errors: 0 Unrouted Nets: Errors: 0 Warnings: 0 Ignored Errors: 0 Net Length: Errors: 0 Warnings: 0 Ignored Errors: 0 Silk Screen: Errors: 0 Warnings: 0 Ignored Errors: 0 Text: Errors: 0 Warnings: 0 Ignored Errors: 0 Width: Errors: 0 Warnings: 0 Ignored Errors: 0 Copper Pour: Errors: 0 ---------------------------------------------------------------------- 24-Jan-25 05:33 Page 3 P-CAD Design Rule Check Report ====================================================================== Warnings: 0 Ignored Errors: 0 Plane: Errors: 0 Warnings: 0 Ignored Errors: 0 Component: Errors: 0 Warnings: 0 Ignored Errors: 0 Drilling: Errors: 0 Warnings: 0 Ignored Errors: 0 ---------------------------------------------------------------------- 24-Jan-25 05:33 Page 4