mirror of
https://github.com/holub/mame
synced 2025-04-22 16:31:49 +03:00
pit8253: fix old regression with mode 3 and odd timer count
This commit is contained in:
parent
3b57da6177
commit
d9788da837
@ -292,9 +292,6 @@ void pit_counter_device::load_counter_value()
|
||||
{
|
||||
m_value = m_count;
|
||||
m_null_count = 0;
|
||||
|
||||
if (CTRL_MODE(m_control) == 3 && m_output == 0)
|
||||
m_value &= 0xfffe;
|
||||
}
|
||||
|
||||
|
||||
@ -769,9 +766,8 @@ void pit_counter_device::update()
|
||||
}
|
||||
|
||||
|
||||
/* We recycle bit 0 of m_value to hold the phase in mode 3 when count is
|
||||
odd. Since read commands in mode 3 always return even numbers, we need to
|
||||
mask this bit off. */
|
||||
/* Since read commands in mode 3 always return even numbers,
|
||||
we need to mask bit 0 off. */
|
||||
uint16_t pit_counter_device::masked_value() const
|
||||
{
|
||||
if ((CTRL_MODE(m_control) == 3) && (downcast<pit8253_device *>(owner())->m_type != pit_type::FE2010))
|
||||
|
Loading…