P-CAD Design Rule Check Report
|
||
|
||
======================================================================
|
||
|
||
C:\prj\SIMM30\simm30-8x-256K.drc:
|
||
|
||
|
||
Design Clearances (in mm):
|
||
-------------------------------
|
||
Board Edge Clearance: Not Defined
|
||
Silk Screen Clearance: Not Defined
|
||
Hole-Hole Clearance: Not Defined
|
||
|
||
|
||
Layer Clearances (in mm):
|
||
-------------------------------
|
||
|
||
Layer Name Pad-Pad Pad-Line Line-Line Pad-Via Via-Line Via-Via
|
||
|
||
Top 0.200 0.200 0.200 0.200 0.200 0.200
|
||
Bottom 0.200 0.200 0.200 0.200 0.200 0.200
|
||
|
||
|
||
Net Class Clearances (in mm):
|
||
-------------------------------
|
||
Net Class Name Pad-Pad Pad-Line Line-Line Pad-Via Via-Line Via-Via
|
||
|
||
|
||
|
||
Net Clearances (In mm):
|
||
-------------------------
|
||
Net Name Pad-Pad Pad-Line Line-Line Pad-Via Via-Line Via-Via
|
||
|
||
|
||
Net Class To Net Class Clearances (in mm):
|
||
--------------------------------------------
|
||
Net Class Names Pad-Pad Pad-Line Line-Line Pad-Via Via-Line Via-Via
|
||
|
||
|
||
|
||
Area Checked:
|
||
-------------
|
||
|
||
DRC Extents: Entire Workspace
|
||
|
||
|
||
DRC Report Options:
|
||
-------------------
|
||
|
||
Net List Compare: Off
|
||
Clearance Violations: On
|
||
Text Violations: On
|
||
Same-Parent-Component Pad Violations: On
|
||
Net List Violations: On
|
||
Unrouted Nets: On
|
||
Unconnected Pins: Off
|
||
Net Length Violations: On
|
||
Silk Violations: On
|
||
Copper Pour Violations: On
|
||
Plane Violations: On
|
||
Component Violations: On
|
||
Drill Violations: On
|
||
|
||
----------------------------------------------------------------------
|
||
|
||
21-Oct-23 17:34 Page 1
|
||
|
||
P-CAD Design Rule Check Report
|
||
|
||
======================================================================
|
||
|
||
Test Point Violations: Off
|
||
|
||
DRC Errors:
|
||
-----------
|
||
|
||
|
||
NETLIST VIOLATIONS:
|
||
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
CLEARANCE VIOLATIONS:
|
||
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
UNROUTED NETS:
|
||
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
Warning: Net length violation tests were not performed because
|
||
of missing MinNetLength, MaxNetLength, or MatchedLength rules.
|
||
|
||
NETLIST LENGTH VIOLATIONS:
|
||
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
SILK SCREEN CLEARANCE VIOLATIONS:
|
||
|
||
|
||
Warning: Silk Screen clearance violation tests were not performed because
|
||
of missing SilkscreenClearance rule.
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
TEXT VIOLATIONS:
|
||
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
WIDTH VIOLATIONS:
|
||
|
||
Warning: Width violation tests were not performed because
|
||
of missing Width rule.
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
COPPER POUR VIOLATIONS:
|
||
|
||
|
||
----------------------------------------------------------------------
|
||
|
||
21-Oct-23 17:34 Page 2
|
||
|
||
P-CAD Design Rule Check Report
|
||
|
||
======================================================================
|
||
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
PLANE VIOLATIONS:
|
||
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
COMPONENT VIOLATIONS:
|
||
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
DRILL VIOLATIONS:
|
||
|
||
Warning: Hole to hole clearance violation tests were not performed because
|
||
of missing HoleToHoleClearance rule.
|
||
|
||
0 warning(s) detected.
|
||
0 error(s) detected.
|
||
|
||
DRC Summary:
|
||
------------
|
||
|
||
Netlist:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Clearance:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Unrouted Nets:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Net Length:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Silk Screen:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Text:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Width:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Copper Pour:
|
||
Errors: 0
|
||
|
||
----------------------------------------------------------------------
|
||
|
||
21-Oct-23 17:34 Page 3
|
||
|
||
P-CAD Design Rule Check Report
|
||
|
||
======================================================================
|
||
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Plane:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Component:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
Drilling:
|
||
Errors: 0
|
||
Warnings: 0
|
||
Ignored Errors: 0
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
----------------------------------------------------------------------
|
||
|
||
21-Oct-23 17:34 Page 4
|
||
|