Adjust charge pump current based on the number of pixels
ultimately extracted from a line which can be less than
sample rate. This seems to result in reduced jitter
on optimized modes.
* fix clock selection function implementation
* add support for ALC filter configuration
* add coarse clamp LPF selection
* add support for clamp/ALC offset
* workaround for phase shift issue on optimized modes
* add hscale option for 256x240 opt Line3x mode
* distribute video modes to groups and allow passthru for all modes
-add YPbPr input mode for AV1 and AV3
-utilize more remote control keys
-fix sync LFP load from saved setting
-add vsync threshold setting
-add option to reset settings
-refactor some code
* Improved remote control handling code
* Fixed occasional mode change loop when switching to a non-interlace mode utilizing odd-field sync signal
* Fixed randomly missing blue channel at power-on when using DVI output mode
* Added H-PLL coast options
* Finer tuning range for scanline strength and mask